| Frame sizes
200-280, supply 4160/3/60 |
|
| Performance data |
|
|
| Frame size |
Poles |
Output |
Power factor |
Efficiency |
FLC |
LRC |
LRT |
FL speed |
|
| kW |
4/4 |
3/4 |
2/4 |
4/4 |
3/4 |
2/4 |
A |
%FLC |
%FLT |
RPM |
|
| D/E200 |
2 |
18 |
0.90 |
0.90 |
0.85 |
88.5 |
87.5 |
84.5 |
3.1 |
800 |
130 |
3565 |
|
| D/E225A |
2 |
25 |
0.90 |
0.87 |
0.80 |
90.0 |
88.5 |
86.0 |
4.3 |
800 |
130 |
3568 |
|
| D/E225B |
2 |
30 |
0.90 |
0.87 |
0.80 |
91.0 |
90.5 |
88.0 |
5.1 |
850 |
130 |
3568 |
|
| D/E225C |
2 |
37 |
0.90 |
0.88 |
0.81 |
92.0 |
91.5 |
89.5 |
6.2 |
850 |
130 |
3568 |
|
| D/E250A |
2 |
45 |
0.88 |
0.84 |
0.76 |
91.5 |
90.5 |
88.0 |
7.8 |
850 |
120 |
3572 |
|
| D/E250B |
2 |
56 |
0.90 |
0.88 |
0.82 |
92.5 |
91.5 |
89.5 |
9.3 |
800 |
120 |
3575 |
|
| D/E250C |
2 |
68 |
0.90 |
0.88 |
0.81 |
93.0 |
92.5 |
90.5 |
11.3 |
850 |
120 |
3575 |
|
| D/E280A |
2 |
90 |
0.90 |
0.88 |
0.81 |
93.0 |
92.4 |
90.5 |
14.9 |
800 |
180 |
3567 |
|
| D/E280B |
2 |
112 |
0.90 |
0.87 |
0.80 |
93.0 |
92.4 |
90.5 |
18.6 |
850 |
200 |
3568 |
|
| |
|
| D/E200 |
4 |
18 |
0.84 |
0.80 |
0.71 |
90.5 |
90.0 |
87.5 |
3.3 |
800 |
160 |
1778 |
|
| D/E225A |
4 |
25 |
0.86 |
0.82 |
0.74 |
91.5 |
91.0 |
89.0 |
4.4 |
800 |
160 |
1778 |
|
| D/E225B |
4 |
30 |
0.86 |
0.82 |
0.74 |
92.0 |
91.4 |
89.3 |
5.3 |
800 |
160 |
1779 |
|
| D/E225C |
4 |
37 |
0.86 |
0.84 |
0.78 |
92.5 |
92.0 |
90.5 |
6.5 |
800 |
160 |
1777 |
|
| D/E250A |
4 |
45 |
0.83 |
0.79 |
0.70 |
92.5 |
92.0 |
90.0 |
8.1 |
800 |
170 |
1783 |
|
| D/E250B |
4 |
56 |
0.85 |
0.82 |
0.75 |
93.4 |
93.0 |
91.4 |
9.8 |
750 |
150 |
1781 |
|
| D/E250C |
4 |
68 |
0.85 |
0.81 |
0.73 |
94.0 |
93.5 |
92.0 |
11.8 |
800 |
170 |
1782 |
|
| D/E280A |
4 |
90 |
0.86 |
0.82 |
0.73 |
94.5 |
94.4 |
93.3 |
15.4 |
750 |
200 |
1780 |
|
| D/E280B |
4 |
112 |
0.85 |
0.81 |
0.72 |
94.5 |
94.0 |
93.0 |
19.4 |
800 |
220 |
1780 |
|
|
| All
motors are class F insulation, with temperature rise limited to class B (80K)
and for use in a maximum ambient temperature of 40 Degrees C |
|
| Available
in both safe area and underground mining configurations |
|
| All
rotors are fabricated copper, Barlok pinned bar construction for arduous
applications |
|
| Intermediate
outputs, special performance requirements and mechanical modifications can be
accomodated - please contact us for more information |
|
| |
|
|
|
60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
|
|